Shunt Reactors

MV cables, UPSs, lighting elements with electronic ballast have capacitive character. Shunt reactors are needed to meet the reactive power requirement and to keep the reactive ratios within the desired limits in the enterprises with such loads.

The load profile of the enterprises is changing day by day. In the past, compensation by simply connecting a capacitor was sufficient. However, the number of devices with capacitive characteristics is constantly increasing in the enterprises. It is therefore necessary to use shunt reactors with capacitors for correct compensation. Shunt reactor size varies according to the size and load profile of the enterprises. After the enterprise is analyzed correctly, the most appropriate shunt reactor should be selected considering the cost.

Shunt Reactors

MV cables, UPSs, lighting elements with electronic ballast have capacitive character. Shunt reactors are needed to meet the reactive power requirement and to keep the reactive ratios within the desired limits in the enterprises with such loads.

The load profile of the enterprises is changing day by day. In the past, compensation by simply connecting a capacitor was sufficient. However, the number of devices with capacitive characteristics is constantly increasing in the enterprises. It is therefore necessary to use shunt reactors with capacitors for correct compensation. Shunt reactor size varies according to the size and load profile of the enterprises. After the enterprise is analyzed correctly, the most appropriate shunt reactor should be selected considering the cost.

Product Detail

Single Phase Shunt Reactors

Product Code Product Name Product Description Power (kVAr) Voltage
(230 V)
Current (A) Thermal Protection Dimensions (mm)
(Width-Height-Depth)
Kg
GA5101 SRM 1.0 1.0 kVAr SINGLE PHASE SHUNT REACTOR 1.0 + 4.34 + 150x130x100 6.0
GA5102 SRM 1.5 1.5 kVAr SINGLE PHASE SHUNT REACTOR 1.5 + 6.52 + 150x130x145 9.0
GA5103 SRM 3.0 3.0 kVAr SINGLE PHASE SHUNT REACTOR 3.0 + 13.04 + 190x165x150 17.0
GA5104 SRM 5.0 5.0 kVAr SINGLE PHASE SHUNT REACTOR 5.0 + 21.73 + 205x260x120 17.5
GA5105 SRM 7.5 7.5 kVAr SINGLE PHASE SHUNT REACTOR 7.5 + 32.60 + 250x310x140 27.0
GA5106 SRM 10.0 10.0 kVAr SINGLE PHASE SHUNT REACTOR 10.0 + 43.40 + 195x250x190 35.0

Three Phase Shunt Reactors

Product Code Product Name Product Description Power (kVAr) Voltage
(400 V)
Current (A) Thermal Protection Dimensions (mm)
(Width-Height-Depth)
Kg
GA5201 SRT 0.5 0.5 kVAr THREE PHASE SHUNT REACTOR 0.5 + 0.72 + 180x155x110 8.0
GA5202 SRT 1.0 1.0 kVAr THREE PHASE SHUNT REACTOR 1.0 + 1.44 + 240x205x115 11.5
GA5203 SRT 1.5 1.5 kVAr THREE PHASE SHUNT REACTOR 1.5 + 2.16 + 240x205x125 14.5
GA5204 SRT 2.5 2.5 kVAr THREE PHASE SHUNT REACTOR 2.5 + 3.60 + 240x205x135 17.0
GA5205 SRT 5.0 5.0 kVAr THREE PHASE SHUNT REACTOR 5.0 + 7.21 + 300x255x140 27.0
GA5206 SRT 7.5 7.5 kVAr THREE PHASE SHUNT REACTOR 7.5 + 10.82 + 300x250x205 39.0
GA5207 SRT 10.0 10.0 kVAr THREE PHASE SHUNT REACTOR 10.0 + 14.43 + 250x310x150 46.0
GA5208 SRT 12.5 12.5 kVAr THREE PHASE SHUNT REACTOR 12.5 + 18.04 + 390x300x170 64.0
GA5209 SRT 15.0 15.0 kVAr THREE PHASE SHUNT REACTOR 15.0 + 21.65 + 390x300x180 68.0
GA5210 SRT 20.0 20.0 kVAr THREE PHASE SHUNT REACTOR 20.0 + 28.86 + 460x350x200 84.0
GA5211 SRT 25.0 25.0 kVAr THREE PHASE SHUNT REACTOR 25.0 + 36.08 + 460x350x210 104.0
GA5212 SRT 50.0 50.0 kVAr THREE PHASE SHUNT REACTOR 50.0 + 72.17 + 560x480x270 200.0

All three-phase shunt reactors are thermally protected